Loading...

pdf Gfa ad 331 Cancelled 2016.03.15 Popular

By Tagged in DG-100, DG-100Elan, DG-100G, DG-100GElan 976 downloads

Download (pdf, 116 KB)

gfa ad 331 Cancelled 15.03.2016.pdf

Gfa ad 331 Cancelled 2016.03.15

INSPECTION PROGRAM FOR  LIFE EXTENSION PAST 3000 HOURS

CANCELLED - Refer Type Certificate Holders current data

Applicable to all Glaser-Dirks DG-100, DG-100G, DG-100 Elan, DG-100G Elan, all serial numbers. Following successful fatigue testing of the main wing spar sections, the manufacturer has negotiated approval with the German airworthiness authorities for the possible extension of the service life from 3000 hours to 6000 hours, as detailed in Glaser-Dirks Technical Note No. 301/11. The extension depends totally on the sailplane being able to pass the inspections at 1000 hour intervals:- Inspection (1) at 3000 hours extending to 4000 hours; Inspection (2) at 4000 hours extending to 5000 hours; Inspection (3) at 5000 hours extending to 6000 hours.