pdf Gfa ad 548 Cancelled 2017.04.11 Popular
By Tim Shirley Tagged in LS6-c 897 downloads
gfa ad 548 Cancelled 11.04.2017.pdf
EXTENSION OF SERVICE TIME/SUPPLEMENTS OF MAINTENANCE MANUALS
CANCELLED - Refer Type Certificate Holders current data
Tests have shown that the life of FRP sailplanes may be extended to 12000 hours based on a multi-stage inspection program. The LS 6-C Maintenance Manual requires amendment to incorporate this program. Luftfahrt-Bundesamt (LBA) Airworthiness Directive No. 2001-110 and Rolladen-Schneider Technical Bulletin No. 6035 Edition 30 October 2000 form part of this AD.