Gfa ad 024

MANDATORY REPLACEMENT OF ELEVATOR ACTUATING BRACKET

Applicable to all marks of Slingsby T59 Kestrel gliders. Slingsby Technical Instruction No. 63 called for inspection of cracks in the welded area on the steel elevator actuating bracket P/N 59A-50-11. This current directive originates from Slingsby Technical Instruction No.65 (Modification No. 18) which replaces the welded elevator actuator bracket P/N 59A-30-11 with a machined aluminium bracket P/N 59A-30-25. The actions embodied in this directive must be completed before 30/06/1974.